logo
ZBDynamiX CHEETAH-1PD-01 48V Robotic Battery Pack | 5Ah Capacity, 50A Continuous Discharge Current, 110A Pulse Discharge Current
ZBDynamiX CHEETAH-1PD-01 48V Robotic Battery Pack | 5Ah Capacity, 50A Continuous Discharge Current, 110A Pulse Discharge Current

ZBDynamiX CHEETAH-1PD-01 48V Robotic Battery Pack | 5Ah Capacity, 50A Continuous Discharge Current, 110A Pulse Discharge Current

ZBDynamiX CHEETAH-1PD-01 48V Robotic Battery Pack | 5Ah Capacity, 50A Continuous Discharge Current, 110A Pulse Discharge Current
Основные свойства
country of origin
Китай
Наименование марки
ZBDynamiX
PRODUCT MODEL
ГЕПАРД-1ПД-01
Торговая недвижимость
MOQ
2
unit price
To be negotiate
Упаковка
стандартный экспортный пакет
Срок отправки
15 рабочих дней
Метод оплаты
Л/К, Д/П, Т/Т
Supply Capacity
1000+ единиц
Сведения о продукте
Key Attributes Battery Cell Model INR21700-50XG-5Ah Nominal Voltage 48V Minimum Capacity 4.95Ah Rated Capacity 5.0Ah Standard Charging Voltage 54.6V Standard Charging Current 5A Maximum Charging Current 5A Pulse Discharge Current 110A(2~3S) Maximum Continuous Discharge Current 50A Single-Cell ...
Характер продукции

Key Attributes

Battery Cell Model INR21700-50XG-5Ah
Nominal Voltage 48V
Minimum Capacity 4.95Ah
Rated Capacity 5.0Ah
Standard Charging Voltage 54.6V
Standard Charging Current 5A
Maximum Charging Current 5A
Pulse Discharge Current 110A(2~3S)
Maximum Continuous Discharge Current 50A
Single-Cell Overcharge Protection Voltage 4.25V±0.02V
Overcharge Protection Delay 1S±0.05S
Single-Cell Overcharge Protection Release Voltage 4.15V±0.02V
Single-Cell Overdischarge Protection Voltage, Two Thresholds 2.783V±0.02V
Overdischarge Protection Delay, Two Thresholds 1000±500mS
Single-Cell Overdischarge Alarm/Protection Release Voltage 2.983V±0.02V
Charge Overcurrent Protection Current 7A±1A
Charge Overcurrent Protection Delay 2±1S
Discharge Overcurrent Protection Current, Level 1 60A
Discharge Overcurrent Protection Current, Level 2 120A
Discharge Overcurrent Protection Current, Level 3 50 A
Discharge Overcurrent Protection Delay, Level 1 5±2s
Discharge Overcurrent Protection Delay, Level 2 400±40ms
Discharge Overcurrent Protection Delay, Level 3 5±1s
Short-Circuit Protection Current 320A
Short-Circuit Protection Delay 300±30uS
Discharge Overtemperature Protection Temperature 65±2℃
Discharge Overtemperature Protection Recovery Temperature 60±2℃
Discharge Undertemperature Protection Temperature -18±2℃
Discharge Undertemperature Recovery Temperature -15±2℃
Discharge Undertemperature Protection Release Temperature /
Charge Overtemperature Protection Temperature 55±2℃
Charge Overtemperature Protection Delay 5±1s
Charge Overtemperature Protection Release Temperature 45±2℃
Charge Undertemperature Protection Temperature 0±2℃
Charge Undertemperature Protection Delay 5±2℃
Charge Undertemperature Protection Release Temperature 5±2s
Standby Self-Consumption Current Low power mode:≤1.5mA
Sleep mode:≤50uA
Battery Pack Weight 0
Charging Operating Temperature and Humidity 0℃~+45℃, 45% to 85%RH
Discharging Operating Temperature and Humidity -20℃~+60℃, 45% to 85%RH
Short-Term Storage Temperature and Humidity, Less Than 1 Month -20℃ ~+60℃, 65%±20%RH
Storage Temperature and Humidity, Less Than 3 Months -20℃ ~+45℃, 65%±20%RH
Recommended Long-Term Storage Temperature and Humidity -20℃ ~+25℃, 65%±20%RH
Long-Term Storage Maintenance Requirement Supplementary charging required once every 3 months
Charge Termination Condition charging current < 100mA
Discharge Termination Condition PACK voltage drops below the over-discharge protection voltage


Готовы отправить быстро
Дознание

Есть вопрос? Заполните форму ниже, и мы свяжемся с вами как можно скорее.

Пожалуйста, введите действительный адрес электронной почты.
Пожалуйста, введите сообщение с запросом.
Защищено конфиденциальностью Быстрый ответ Удовлетворение гарантировано